RPE Series
Voltage | : | 12V, 24V, 36V |
Capacity | : | 10Amp ~ 60Amp |
Battery Capacity | : | 50AH ~ 375AH |
Feature | : | - Recharge time 8 to 10 second delay
- Automatic start after 8 second delay
- Pre-charging mode; detection system ensuring prevention of overcharging
- Proportional gassing
- Pulsed equalizing mode
- Security timer
- Multi voltage PC Board
|
RPM Series
Voltage | : | 12V, 24V, 36V |
Capacity | : | 10Amp ~ 60Amp |
Battery Capacity | : | 50AH ~ 375AH |
Feature | : | - WA Charging mode, in compliance with curve DIN 41774
- Automatic start after 8 second delay
- Pre-charging mode (1h); detection system ensuring prevention of overcharging
- Proportional gassing
- Pulsed equalizing mode (36h)
- The system is protected by a 13h security system
- Microprocessor controlled and multi voltage pc httpss://www.cialissansordonnancefr24.com/generique-cialis/board
- Charging progress display
|
RTM Series
Voltage | : | 24V, 36V, 48V, 72V, 80V |
Capacity | : | 60Amp ~ 180Amp |
Battery Capacity | : | 250AH ~ 1125AH |
Feature | : | - WA Charging mode, in compliance with curve DIN 41774
- Automatic start after 8 second delay
- Pre-charging mode (1h); detection system ensuring prevention of overcharging
- Proportional gassing
- Pulsed equalizing mode (36h)
- Thermal Protection
- The system is protected by a 13h security system
- Microprocessor controlled and multi voltage pc board
- Charging progress display
|
Microplus
Voltage | : | 24V, 36V, 48V, 72V, 80V, 96V |
Capacity | : | 60Amp ~ 180Amp |
Battery Capacity | : | 250AH ~ 1125AH |
Feature | : | - WA Charging mode, in compliance with curve DIN 41774
- Automatic start after 8 second delay
- Pre-charging mode; monitoring system ensuring prevention of overcharging and incorporating a charge inhibit for overdischarge batteries;
- MICROPLUS determines the number of Amperes per hour required for full charging, with charge factor adjustement to meet individual charging needs;
- The Advantage of this type od charge is that, it supplies the battery with the number of amperes per hour required, with the ability to adjust automatically for mains fluctuations and depth of discharge;
- The unit monitors the on charge battery current, terminating the charge only when stabilized conditions at the end of the charge are detected;
- Pulsed equalizing mode (24h), with facility for equalizing delay;
- Conpensation charge;
- Facility to abjust (gassing voltage, adjust charge factor, delayed start of charge and delayed equalizing mode)
- Double security timer (10-13 hour);
- Led�s indicating charge progress;
- Alpha/numeric display : key information including total voltage, charge current, amps returned, accumulated charge time, charge factor;
- Multi voltage PC Board;
- Stop/Star push button;
- Current reading made by a sophisticated inductive sensor.
|
Nuova Elettra Read More »